Noch heisst dieser Server esxi01.office, dies wird jedoch bei der Netzwerkumstellung auf esxi01.typographie.lan angepasst.
supermicro IP: 192.168.1.3 esxi01 IP: 192.168.1.4
Services
- ESXi Host VMkernel esxi01 6.0.0 #1 SMP Release build-3380124 Dec 28 2015 11:17:57 x86_64 x86_64 x86_64 ESXi
- Raid Storage (Raid 6 – 10.9 T)
- Raid System für VM’s (Raid 1 – 446.5 GB)
- ESXi läuft auf einem Flash Speicher (22.2 GB)
- NFS Automont nfs://backup.office Volume: /Volumes/Raid_Backup/nfs_shared
Supermicro
Firmware Revision : 03.14 IP address : 192.168.001.003 Firmware Build Time : 08/27/2015 BMC MAC address : 0c:c4:7a:6e:42:0e BIOS Version : 1.1 System LAN1 MAC address : 0c:c4:7a:6c:17:24 BIOS Build Time : 04/14/2015 System LAN2 MAC address : 0c:c4:7a:6c:17:25 CPLD Version : 02.a1.00
ESXi
Filesystem Size Used Available Use% Mounted on NFS 5.5T 2.1T 3.4T 38% /vmfs/volumes/Shared VMFS-5 22.2G 931.0M 21.3G 4% /vmfs/volumes/datastore1 VMFS-5 10.9T 7.2T 3.7T 66% /vmfs/volumes/Raid VMFS-5 446.5G 310.1G 136.4G 69% /vmfs/volumes/SSD vfat 285.8M 201.6M 84.2M 71% /vmfs/volumes/56694bb1-4ce7092c-58e8-a0369f8d7f26 vfat 249.7M 172.3M 77.4M 69% /vmfs/volumes/58debc7c-898137d7-5cc2-8dfc2b4e8333 vfat 4.0G 16.6M 4.0G 0% /vmfs/volumes/56694bb5-79087368-1a05-a0369f8d7f26 vfat 249.7M 172.3M 77.4M 69% /vmfs/volumes/336abb7b-d46431da-e516-d19b8f00099d
Vmid Name File Guest OS Version Annotation 1 transfer [SSD] transfer/transfer.vmx darwin10_64Guest vmx-11 2 mam [SSD] mam/mam.vmx darwin13_64Guest vmx-11 3 pap [SSD] pap/pap.vmx darwin14_64Guest vmx-11
[root@esxi01:~] esxcfg-nics -l Name PCI Driver Link Speed Duplex MAC Address MTU Description vmnic0 0000:04:00.0 igb Up 1000Mbps Full 0c:c4:7a:6c:17:24 1500 Intel Corporation I350 Gigabit Network Connection vmnic1 0000:04:00.1 igb Up 1000Mbps Full 0c:c4:7a:6c:17:25 1500 Intel Corporation I350 Gigabit Network Connection vmnic2 0000:01:00.0 igb Up 1000Mbps Full a0:36:9f:8d:7f:26 1500 Intel Corporation I350 Gigabit Network Connection vmnic3 0000:01:00.1 igb Down 0Mbps Half a0:36:9f:8d:7f:27 1500 Intel Corporation I350 Gigabit Network Connection
[root@esxi01:~] esxcfg-vswitch -l Switch Name Num Ports Used Ports Configured Ports MTU Uplinks vSwitch0 4082 5 128 1500 vmnic0 PortGroup Name VLAN ID Used Ports Uplinks VM Network 0 2 vmnic0 Switch Name Num Ports Used Ports Configured Ports MTU Uplinks vSwitch1 4082 6 128 1500 vmnic1 PortGroup Name VLAN ID Used Ports Uplinks VM Network 2 WAN 0 3 vmnic1 Switch Name Num Ports Used Ports Configured Ports MTU Uplinks vSwitch2 4082 4 128 1500 vmnic2 PortGroup Name VLAN ID Used Ports Uplinks VM Network 2 esxi Management 0 0 vmnic2 VMkernel 0 1 vmnic2
[root@esxi01:~] esxcfg-vmknic -l Interface Port Group/DVPort/Opaque Network IP Family IP Address Netmask Broadcast MAC Address MTU TSO MSS Enabled Type NetStack vmk1 VMkernel IPv4 192.168.1.4 255.255.255.0 192.168.1.255 00:50:56:6f:30:1b 1500 65535 true STATIC defaultTcpipStack vmk1 VMkernel IPv6 fe80::250:56ff:fe6f:301b 64 00:50:56:6f:30:1b 1500 65535 true STATIC, PREFERRED defaultTcpipStack
Total 0 Votes:
0
0